FCW 414-O

Tubular wire for self-shielded metal arc hardfacing.

Beschrijvingen & toepassingen

Tubular wire for self-shielded metal arc hardfacing.

13% chromium martensitic stainless steel deposit.

Deposit resists corrosion, erosion and abrasive wear.

Classificatie

EN 14700 DIN 8555
T Fe7 CZ MF 5 GF 40 CZ

Richtanalyse (%)

C Mn Si Cr Ni Mo Fe
0.04 0.80 0.60 13.0 4.10 0.50 Bal.

Mechanische eigenschappen

Hardness - 3 Layer deposit
As welded : 38-42 HRc

Beschermgas

Current type DC (+)
Shielding Self shielded

Gebruiksvoorwaarden

Diameter [mm] Amperage [A] - Range Voltage [V] – Range Stick Out [mm]
1.6 150-300 24-27 15-25
2.4 250-350 25-27 25-30

Lasposities

Flat, half up, half down

Verpakkingen & Diameters

Diameters [mm] ≤ 2.4 mm ≥ 2.4 mm ≥ 2.4 mm
Verpakking(en) Spool Coil Drum
Gewicht [Kg] 15 kg 25 kg 330 kg