Metal cored tubular wire for gas shielded metal arc hardfacing
• Metal cored tubular wire for gas shielded metal arc hardfacing
• Medium hardness deposit offering exceptional oxidation resistance and hot toughness up to 600 C
APPLICATIONS
FCW WM is used for surfacing parts subjected to heavy compressive stresses and moderate abrasion or metal-to-metal wear, combined with mechanical and thermal shocks.
Examples
Hot and cold forging tools, hot work extrusion mandrels, drills, cutting edges on hot cutting tools…
EN 14700 |
---|
T Fe3 |
C | Mn | Si | Cr | Ni | W | V |
---|---|---|---|---|---|---|
0.3 | <0.5 | <1.0 | 2.4 | 0.2 | 4.0 | 0.6 |
Hardness – 3-Layer deposit on mild steel |
---|
43-48 HRc |
Current type | DC (+) |
---|---|
Shielding gas | EN 439 / ISO 14175 : M21: Ar + 5-25%CO |
Diameter [mm] | Amperage [A] - Range | Amperage [A] - Optimum | Voltage [V] - Range | Voltage [V] - Optimum | Stick-out [mm] - Range | Stick-out [mm] - Optimum |
---|---|---|---|---|---|---|
1.2 | 100-300 | 220 | 22-32 | 28 | 15-30 | 20 |
1.6 | 150-300 | 280 | 24-32 | 28 | 15-30 | 25 |
2.0 | 200-400 | 300 | 24-32 | 28 | 12-30 | 25 |
2.4 | 250-450 | 350 | 24-32 | 28 | 12-30 | 25 |
Flat, half up, half down
Diameters [mm] | 1.2 - 1.6 - 2.0 - 2.4 | 2.4 | 2.4 |
---|---|---|---|
Packing(s) | Spool BS 300 | Coil B 450 | Drum |
Weight [Kg] | 15 | 25 | Up to 330 |
Description | - | - | - |